Descubre los productos 22
La imagen Número de pieza Fabricante Cantidad Plazo de entrega Precio unitario Comprar Descripción Packaging Series Applications Operating Temperature Features Voltage - Input (Max) Control Features Voltage - Input (Min) Voltage - Isolation Efficiency
RS-2415D
RECOM Power
2,756
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W DL +/-15V OUT SIP8
Tube ECONOLINE RS ITE (Commercial) -45°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 18V 1kV 83%
RS-2415DZ/H3
RECOM Power
165
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-36VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 9V 3kV 83%
RS-1215D
RECOM Power
152
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-18VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial) -40°C ~ 85°C Remote On/Off,SCP 18V Enable,Active Low 9V 1kV 80%
RS-0515D
RECOM Power
231
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 4.5-9VIN +/-15V
Tube ECONOLINE RS ITE (Commercial) -40°C ~ 85°C Remote On/Off,SCP 9V Enable,Active Low 4.5V 1kV 80%
RS-4815DZ/H3
RECOM Power
100
3 dias
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 18-72VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 72V Enable,Active Low 18V 3kV 83%
RS-4815D
RECOM Power
24
3 dias
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 36-72VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial) -40°C ~ 85°C Remote On/Off,SCP 72V Enable,Active Low 36V 1kV 83%
RS-0515D/H3
RECOM Power
53
3 dias
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 4.5-9VIN +/-15V
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 9V Enable,Active Low 4.5V 3kV 80%
RS-2415DZ
RECOM Power
10
3 dias
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-36VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial) -40°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 9V 1kV 83%
RS-2415D/H2
RECOM Power
22
3 dias
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 18-36VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 18V 2kV 83%
DPAN02B-15
Mean Well USA Inc.
4
3 dias
-
MOQ: 1  MPQ: 1
1
- DPAN02 ITE (Commercial) -40°C ~ 90°C (With Derating) Remote On/Off,OCP,SCP,UVLO 36V - 18V 1500V 85%
DPAN02C-15
Mean Well USA Inc.
4
3 dias
-
MOQ: 1  MPQ: 1
1
- DPAN02 ITE (Commercial) -40°C ~ 90°C (With Derating) Remote On/Off,OCP,SCP,UVLO 75V - 36V 1500V 84%
DPAN02E-15
Mean Well USA Inc.
2
3 dias
-
MOQ: 1  MPQ: 1
1 W;I/P: 5VDC;O/P:15V67MA;SIP
- DPAN02 ITE (Commercial) -40°C ~ 90°C (With Derating) Remote On/Off,OCP,SCP,UVLO 9V - 4.5V 1500V 80%
DPAN02A-15
Mean Well USA Inc.
Consulta
-
-
MOQ: 1  MPQ: 1
1
- DPAN02 ITE (Commercial) -40°C ~ 90°C (With Derating) Remote On/Off,OCP,SCP,UVLO 18V - 9V 1500V 83%
RS-1215D/H2
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-18VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 18V Enable,Active Low 9V 2kV 80%
RS-0515D/H2
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 4.5-9VIN +/-15V
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 9V Enable,Active Low 4.5V 2kV 80%
RS-1215D/H3
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-18VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 18V Enable,Active Low 9V 3kV 80%
RS-2415D/H3
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 18-36VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 18V 3kV 83%
RS-2415DZ/H2
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 9-36VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 36V Enable,Active Low 9V 2kV 83%
RS-4815DZ
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 18-72VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial) -40°C ~ 85°C Remote On/Off,SCP 72V Enable,Active Low 18V 1kV 83%
RS-4815D/H2
RECOM Power
Consulta
-
-
MOQ: 1  MPQ: 1
CONV DC/DC 2W 36-72VIN +/-15VOUT
Tube ECONOLINE RS ITE (Commercial),Medical -40°C ~ 85°C Remote On/Off,SCP 72V Enable,Active Low 36V 2kV 83%